Automatic Door Lift
Passenger Lift - Automatic Doors
Automatic door are recommended for lifts
being used at public buildings handling high traffic. Though they require
more space in the building as compared to manual doors, it is advisable to
go for automatic doors. There is no need for a lift operator. The door
panels can be designed to add to the décor of the building.
The range of lifts available is from 4 persons to 40 persons. The speed of
travel ranges from single speed of 0.7m/s to variable speeds of 1.5m/s. The
cabin walls & door panels can be of M.S. painted, M.S. Powdercoated or
Hairline brush finished stainless steel. Glass doors can also be provided
but are expensive. Normally center opening doors are advised due to their
ease of use and elegance. However in places with a size constraint,
telescopic doors can also be provided in which both the doors open towards
one side.
Our lifts use Programmable Logic Controllers with auto fault display and
detection capability. Modern amenities like variable speeds through ACVVVF
drives, Automatic rescue device for electricity failure, Load weighing
devices for large lifts, Hydraulic machine room less lifts, etc are
available at extra cost.
Notes
| Machine Room Height |
'M' - 2430 |
| Pit Depth |
'P' - 1650 |
| Overhead ( F.F.L. of Highest
floor to Machine Room Bottom ) |
'O' - 4850 |
Any number of floors can be served. The Side elevation shows only the Top
Floor & Bottom Floor for the respective height requirements :
- All Door heights will be 2000mm clear.
- Plan for Manual Swing doors / Collapsible doors / Telescopic
doors is different.
- All Sizes are inside finished dimensions in mm.
- All Hoistway walls are 230 mm thick Brick or 150 mm RCC walls.
|
Clients Scope
- Entire Civil Structure for the lift shaft including plaster &
painting of lift shaft inside.
- Three Phase Electric Supply.
- Scaffolding during Lift erection.
- Provision of sill support, machine support, Lifting beam / hook,
pit ladder, etc.
- Grouting of our holdfasts, Push button Boxes, Door frame members,
etc.
- Machine room will be extended beyond the lift shaft so that
machine is approachable from three sides for maintenance.
|
| Size Table |
| Person |
Load |
Car Inside A
x B |
Lift Shaft C
x D |
Entrance
E |
Machine Room K
x L |
| No. |
Kgs. |
Width x Length
|
Width x Length |
Width |
Width x Length |
| 4 |
272 |
1100 x 700 |
1850 x 1350 |
800 |
3000 x 3000 |
| 6 |
408 |
1100 x 1000 |
1850 x 1650 |
800 |
3000 x 3000 |
| 8 |
544 |
1300 x 1100 |
1850 x 1750 |
800 |
3000 x 3000 |
| 10 |
680 |
1350 x 1300 |
2050 x 1950 |
900 |
4000 x 3000 |
| 13 |
884 |
1500 x 1500 |
2050 x 2150 |
900 |
4000 x 3000 |
| 16 |
1088 |
1750 x 1500 |
2250 x 2150 |
1000 |
4000 x 3600 |
| 20 |
1360 |
2000 x 1600 |
2250 x 2250 |
1000 |
4500 x 3600 |
| 24 |
1632 |
2100 x 1800 |
2450 x 2350 |
1100 |
4500 x 3600 |
|
 |
|
|
|