Aquatropy Products
Water Heater
Using LDO/HSD/FO/LPG/CNG/LNG
DESIGNED AND CONSTRUCTION: - The internal combustion chamber is used to accommodate concentric helical tube machine wound coil, (fabricated out of ERW Boiler tube as per BS 3059). This coil is placed in a double shell of mild steel construction. This type of design helps in economising the space and simultaneously ensures optimum rate of heat release. Due to elimination of extensive use of refractory, it permits rapid start up and operational and maintenance flexibility.
AQUATROPY Hot Water Heater designed with uses instruments from reputed components Landis & Gyr (Germany), Monarch (USA), Danfoss (Denmark), Larsen & Tubro, Siemens, NGEF, Crompton, Kirloskar, Indfoss, Tata/TI, KSB.
FULLY AUTOMATIC, ECONOMICAL, SAFE & ECO FRIENDLY, LOW MAINTENANCE
No manpower required during operation. The system is economical at all levels whether it is initial cost, operation or maintenance cost. Its operational cost is 1/3 of the cost of any electric heating system. The system is completely explosion proof and safe from every point of view. It is silent, smoke free and noiseless. To maintain the Water Heater, you have to take care of preventive measures only. You are free from day to day maintenance problems.
| TECHNICAL SPECIFICATIONS |
| Details |
AWH
0.25 |
AWH
0.50 |
AWH
01 |
AWH
02 |
AWH
03 |
AWH
04 |
AWH
06 |
AWH
10 |
AWH
15 |
| HEAT OUTPUT K CAL/H |
25,000 |
50,000 |
100,000 |
2,00,000 |
3,00,000 |
4,00,000 |
6,00,000 |
1,00,000 |
15,00,000 |
HOT WATER TEMP. |
90°C |
20° C TO 60° C LTRS/HR |
450 |
910 |
1820 |
3640 |
5440 |
7270 |
10910 |
18180 |
27270 |
NCV OF HSD, LDO |
92% ± 2% |
FUEL CONSUMPTION
HSD, LDO KG/HR |
2.75 |
5.4 |
10.4 |
20.7 |
31.1 |
41.4 |
62.1 |
103.5 |
155.3 |
POWER SUPPLY REQUIRED |
415 Volts AC ± 6%, 50 Hz ± 3%, 3 phase, 4 Wire |
TOAL CONNECTED ELECT. LOAD KW |
0.5 |
0.75 |
1.5 |
2.6 |
3.7 |
5.0 |
7.5 |
12.00 |
19.6 |
| |
Automatic on/off, optional, PLC control for weekly programme |
| OVERALL DIMENSION |
|
|
|
|
|
|
|
|
|
| HEIGHT |
1.0 M |
1.4 M |
2.06 M |
2.25 M |
2.55 M |
2.80 M |
3.20 M |
3.30 M |
3.90 M |
| LENGTH |
0.7 M |
0.9 M |
1.60 M |
1.70 M |
1.80 M |
1.90 M |
2.10 M |
2.60 M |
3.00 M |
| WIDTH |
0.7 M |
0.9 M |
1.00 M |
1.30 M |
1.50 M |
1.80 M |
2.00 M |
2.10 M |
2.25 M |
| DRY WEIGHT |
625 |
780 |
908 |
1250 |
1650 |
2300 |
2800 |
3200 |
4500 |
Note: Fuel oil consumption is based on net calorific value of (HSD) 10,200 Kcal/Kg & LDO 10,050f Kcal/Kg2. We reserve the right change any specification without prior notice
|