Home
About Us
Our Products
Our Clients
Contact Us
Send Enquiry
Home Our Products - Aquatropy Products -Fluid Heater

Aquatropy Products

Fluid Heater

3 PASS LIQUID THERMIC FLUID HEATER USING LDO / FO / LPG / CNG / LNG

THERMIC FLUID HEATING SYSTEM
For all process heating applications, AQUATROPY Liquid phase Heater can be substituted against steam or electricity instead of pressurised hot water or steam. It uses THERMIC FLUIDS for heat transfer. Double closed circuit system of tubes used for heat transfer by forced circulation to prevent chemical degradation. Temperatures upto 280°C can be obtained with an accuracy of +1 % at a low working pressure of 2.5kg/cm (approx.) THERMIC FLUIDS such as heat transfer oil (Hythem 500-600, Servo Super - Medium) are used for heat transfer instead of pressurised hot water or steam.

DESIGN AND CONSTRUCTION
The double coil of inside internal combustion chamber is used to accommodate concentric helical tube machine wound coil, (fabricated out of HFS Seamless Boiler tube as per BS 3059) This coil is placed in a double shell of mild steel construction. This type of design helps in economising the space and simultaneously ensures optimum rate of heat capture. Due to elimination of use of refractory materials. It permits rapid start up and operational maintenance flexibility. The boiler weight also reduces due to absence of Refractory bricks.

COMBUSTION
A fuel Atomising pressure-]et burner is placed vertically downward for combustion A dynamically balanced blower fan pushes the combustion air through the annular space between the inner and outer shell, where air is pre-heated for efficient combustion and higher efficiency The air acts as an effective thermal insulator eliminating the need for conventional insulation Air is swirled through a stainless steel diff user plate and mixes with Atomised fuel to achieve total combustion in the furnace.

BURNER AND FUEL SYSTEM
Fuel Pump Supplies Fuel to the pressure JET Burner from the Tank though a filter. The Burner is fully automatic in operation & switch ON and OFF as per process heat requirements.

INSTRUMENTATION, CONTROL AND SAFETIES
AQUATROPY is a fully automatic Thermic Fluid Heater fitted with safety devices like high fluid temperature controller, pressure switch, low level switch in expansion tank, spring loaded antic hocking safety valve, high stack temperature switch, flame sensor, low fuel oil temperature switch; Main Controller uses Temperature controller & Seq - Controller for abnormal working condition interlock with audio - visual alarm. Aquatropy uses instruments from reputed manufacturers.

TECHNICAL SPECIFICTIONS
DETAIL                
HEAT OUTPUT   Model ATH-0.5 ATH-01 ATH-02 ATH-04 ATH-06 ATH-10 ATH-15
FUEL CONSUMPTION
(APPROX )
  Kcal/hrs 50,000 1,00,000 2,00,000 4,00,000 6,00,000 10,00,000 15,00,000
  L.D.O Kg/hrs 5.7 110.4 22.9 45.7 68.6 114.4 171.5
H.S.D 5.6 11.3 22.5 45 67.6 112.7 169.1
THERMAL EFFICIENCY 92% ± 2% on Nett Calorific Value (NCV)
ELECTRICAL SUPPLY 415% ± 6% 50 HZ #%, AC – 3Phase, 4 Wire
CIRCULATING PUMP MOTOR KW 1.5 3.7 5.5 9.4 11.25 15.25 18.75
FUEL PUMP MOTOR HP - - - - 0.5 1.0 1.0
BURNER (BLOWER) MOTOR KW 0.37 0.75 1.2 3.7 3.7 3.7 11.0
AUTOMATIC ON/OFF, OPTIONAL – PLC CONTROL FOR WEEKLY PROGRAMME 0.50%
ON-OFF 50-100% Low-High
0.33%
ON-OFF 33-100% Modulation
TOTAL CONNECTED LOAD

OVERALL DIMENSIONS

(METERS)
KW 2.0 5.0 8.0 12.0 15.0 23.0 30.75
LENGTH 1.20 1.50 1.60 1.85 2.20 2.45 2.95
WIDTH 0.80 0.95 1.15 1.75 2.00 2.40 2.50
HIGHT 1.40 2.10 2..30 2..80 3.35 3.60 4.40
DRY WEIGHT (APPROX.) KG 750 950 1300 2350 3000 3600 4100



Note 1 Fuel oil consumption is based on Nett Calorific Value of (HSD) 10,200 Kcal/Kg & LD010 050 Kcal/Kg 2. We reserve the right to change any specification without prior notice.

THERMIC FLUID HEATER USING SOLID FUEL WOOD, HUSK, BIO- PELLETS USED FOR PROCESS HEATING APPLICATIONS.

ADVANTAGES:

  • Locally available fuels can be used, by-products can be gainfully used
  • Agro - waste and bio mass can be converted to process heat.
  • Perfect answer to ever changing energy/fuel situation.
  • Our heater design offers multi-fuel flexibility.
  • Vertical closed loop thermal oil heating.
  • Long life coil HFS seamless Boiler tube BS 3059 grade.
  • Complete combustion of solid fuel by manipulating time.
  • Temperature and turbulence of air as well as the fuel itself
  • ID (induced draft) fan, FD (forced draft) fan
  • Digital temperature controller
  • Low thermic fluid level safety switch
  • Differential pressure economy switch
  • Large range inlet & outlet pressure gauge
  • Spring loaded anti chocking safety valve
  • Audio visual alarm for abnormal operating conditions at remote locations all so.
  • Optional remote monitor & operation for all operational parameters.
     
TECHNICAL SPECIFICATIONS
DETAIL MODEL ATSH-2 ATSH-4 ATSH-6 ATSH-10 ATSH-15 ATSH-20 ATSH-25 ATSH-30
HEAT OUTPUT Kcal/hrs 2,00,000 4,00,000 6,00,000 10,00,000 15,00,000 20,00,000 25,00,000 30,00,000
Fuel
Consumption
COAL Kg/hrs 88 154 232 386 560 770 960 -
HUSK - 174 260 434 650 870 7080 1300
WOOD 112 179 268 446 670 890 1120 -
TF CIRCULATION MOTOR KW 5.5 9.2 12.90 18.80 25.10 35.70 43.10 50.40
ID FAN MOTOR COAL/WOOD KW 3 12.9 0.17 23.20 33.9 43.10 50.40 NA
ID FAN MOTOR HUSK KW …….. 13.3 19.2 24.70 35.70 44.90 54.10 70.7
FD FAN MOTOR HUSK COAL/WOOD KW …….. 14.8 18.8 25.10 37.60 46.80 57.50 NA
FD FAN MOST HUSK KW …….. 15.1 21.0 26.50
39.40
48.60
61.50
78.0


Note: - fuel consumption is based on GCV of Coal: 3500 Kcal/KG, Husk: 3200 Kcal/ Kg, Baled bagesse: 3000 Kcal/KG -23% moisture.

No Products In this category
Home | Aboutus | Our Products | Our Clients | Contact Us | Send Enquiry