Aquatropy Products
Steam Boiler
AQUATROPY Steam Generator is the latest design in coil type boilers using Reverse Flame Technology. The furnace is made of an air tight helical coil of membrane wall construction, placed inside an assembly & double jacketed MS shell and aluminium radiator. Combustion air is forced through the jacketed shell, thereby getting pre heated and keeping the outer shell cool.
COMBUTION: - The pressure jet burner atomises the fuel and preheated air helps in completing combustion. The flue gases are reversed in the furnace, resulting in two radiant heat transfer passes and the third convective pass between coil and inner shell. The flue gases further transfer heat to the economiser for preheating feed water. A specially designed heat optimiser protects the feed water pump from high feed water temperature, thus enhancing the life of the pump.
These special features combine to make a very reliable and highly efficient and green boiler.
NO BOILER INSPECTOR FORMALITIES.
'AQUATROPY' Reverse Flame Steam Generator is out side the preview of Indian Boiler regulations.
No Need of separate Boiler House or an IBR approved boiler Operator.
LARGE TUBE DIAMETER
AQUATROPY offers a unique coil design, in which the coil diameter is 31.8mm/OD Due to this, there is Lesser coil chocking ensuring longer life of the coil. Fabricated out of CDW seamless Boiler tube BS3059 grade.
Also the coil of AQUATROPY is machine wound which avoids the flame giving any temperature hot spots within a chamber.
| TECHNICAL SPECIFICTIONS |
|
| DETAIL |
MODEL |
ASG-.5 |
ASG -1 |
ASG-2 |
ASG 3 |
ASG-4 |
ASG-5 |
ASG-6 |
ASG-8 |
| RATED STEAM |
Kg/hrs |
50 |
100 |
200 |
300 |
400 |
500 |
600 |
800 |
| OUTPUT (F&A100°) |
TIME REQUIRED TO COME FULL LOAD FROM COLD START 3 TO 5 MINUTES (APPROX.) |
| STEAM PRESSURE kg/hr2 10.5 10.5 or 15 |
| EFFICIENCY (NCV) |
% 88±1% (NCV) |
|
| FUEL OIL COMMOTION |
HSD |
Kg/hr |
3 |
6 |
12 |
18 |
24 |
30 |
36 |
48 |
| LCD |
Kg/hr |
3.3 |
6.5 |
12.7 |
19.1 |
25.4 |
31.8 |
38 |
44.3 |
| BURNER CONTROL |
AUTOMATIC – OFF |
| PRESSURE PARTS |
OUTSIDE THE PREVIEW OF INDIAN BOILER REGULATION |
| ELECTRIC PARTS |
ELECTRIC SUPPLY 415v ± 6%50 Hz 3%, 3 phase, 4 Wire |
| ELECTRIC SUPPLY |
hp |
1 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.0 |
1.5 |
| FEED WATER PUMP MOTORS |
hp |
* |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
0.5 |
| FUEL PUMP MOTOR |
hp |
0.5 |
1.0 |
1.0 |
1.0 |
2.0 |
3.0 |
3.0 |
3.0 |
| BLOWER MOTOR |
kw |
1.2 |
1.9 |
1.9 |
2.6 |
2.6 |
3.5 |
3.5 |
3.5 |
| TOTAL CONNECTED LOAD |
mm
mm |
1100
1000 |
1700
1600 |
1700
1600 |
2000
1790 |
2000
1790 |
2200
1790 |
2200
1790 |
2600
1790 |
| OVERALL DIMENSIONS |
mm |
1000 |
1150 |
1150 |
1210 |
1210 |
1210 |
1210 |
1210 |
Note: 1. Fuel oil consumption is based on Nett Calorific Value of (HSD) 10.200 Kcal/Kg & LD0 10.050 Kcal/Kg. 2 We reserve the right to change any specification without prior notice. |